ath79: fix first reboot issue on Netgear WNDR4300 v2 and WNDR4500 v3
From the Netgear u-boot GPL code[1]. Bootloader always unconditionally marks block 768, 1020 - 1023 as bad blocks on each boot. This may lead to conflicts with the OpenWrt nand driver since these blocks may be good blocks. In this case, U-boot will override the oob of these blocks so that break the ubi volume. The system will be damaged after first reboot. To avoid this issue, manually skip these blocks by using "mtd-concat". [1] https://www.downloads.netgear.com/files/GPL/EX7300v2series-V1.0.0.146_gpl_src.tar.bz2.zip Fixes: https://github.com/openwrt/openwrt/issues/8878 Tested-by: Yousaf <yousaf465@gmail.com> Signed-off-by: Shiji Yang <yangshiji66@qq.com>
This commit is contained in:
committed by
Hauke Mehrtens
parent
0f9b8aa3f5
commit
12f53724c6
@@ -0,0 +1,15 @@
|
||||
. /lib/functions.sh
|
||||
. /lib/functions/uci-defaults.sh
|
||||
|
||||
board_config_update
|
||||
|
||||
case "$(board_name)" in
|
||||
netgear,wndr4300-v2|\
|
||||
netgear,wndr4500-v3)
|
||||
ucidef_set_compat_version "1.1"
|
||||
;;
|
||||
esac
|
||||
|
||||
board_config_flush
|
||||
|
||||
exit 0
|
||||
Reference in New Issue