ath79: fix gigabit link pll-data for EX7300
The device did not appear to be reachable unless the connection were
forced to 100Mb or lower. Revert to previously working pll-data.
Also fix the phy-mode to represent the actual state needed for ethernet
to function.
Reported-by: Moritz Schreiber <moritz@mosos.de>
Signed-off-by: Daniel Gimpelevich <daniel@gimpelevich.san-francisco.ca.us>
[add remark about phy-mode property]
Signed-off-by: David Bauer <mail@david-bauer.net>
(cherry picked from commit ee41b602a2)
			
			
This commit is contained in:
		
				
					committed by
					
						
						David Bauer
					
				
			
			
				
	
			
			
			
						parent
						
							bf800022b2
						
					
				
				
					commit
					24fddfa1be
				
			@@ -216,7 +216,7 @@
 | 
			
		||||
	mtd-mac-address = <&caldata 0x00>;
 | 
			
		||||
 | 
			
		||||
	phy-handle = <&phy4>;
 | 
			
		||||
	phy-mode = "rgmii";
 | 
			
		||||
	phy-mode = "rgmii-rxid";
 | 
			
		||||
 | 
			
		||||
	pll-data = <0x83000000 0x80000101 0x80001313>;
 | 
			
		||||
	pll-data = <0x86000000 0x80000101 0x80001313>;
 | 
			
		||||
};
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	
	Block a user