ath79: fix 10 Mbit PLL data for TP-Link EAP2xx
Fix the PLL register value for 10 Mbit/s link modes on TP-Link EAP
boards using a AR8033 SGMII PHY.
Otherwise, 10 Mbit/s links do not transfer data.
Reported-by: Tom Herbers <freifunk@tomherbers.de>
Tested-by: Tom Herbers <freifunk@tomherbers.de>
Signed-off-by: David Bauer <mail@david-bauer.net>
(cherry picked from commit bbff6239e2)
			
			
This commit is contained in:
		 David Bauer
					David Bauer
				
			
				
					committed by
					
						 Hauke Mehrtens
						Hauke Mehrtens
					
				
			
			
				
	
			
			
			 Hauke Mehrtens
						Hauke Mehrtens
					
				
			
						parent
						
							f33139c4d5
						
					
				
				
					commit
					8437c24f09
				
			| @@ -112,6 +112,7 @@ | |||||||
|  |  | ||||||
| 	phy-handle = <&phy4>; | 	phy-handle = <&phy4>; | ||||||
| 	phy-mode = "sgmii"; | 	phy-mode = "sgmii"; | ||||||
|  | 	pll-data = <0x03000000 0x00000101 0x00001313>; | ||||||
|  |  | ||||||
| 	mtd-mac-address = <&info 0x8>; | 	mtd-mac-address = <&info 0x8>; | ||||||
|  |  | ||||||
|   | |||||||
		Reference in New Issue
	