mt7622: remove 300 MHz from dts
Due to the bug described here[1], remove the 300 MHz clock to avoid a low voltage condition that can cause a hang when rebooting the RT3200/E8450. This solution is probably better than the script-based work-around[2]. 1. https://forum.openwrt.org/t/belkin-rt3200-linksys-e8450-wifi-ax-discussion/94302/1490 2. https://github.com/openwrt/openwrt/pull/5025 Signed-off-by: John Audia <therealgraysky@proton.me> Tested-by: Rui Salvaterra <rsalvaterra@gmail.com> Tested-by: John Audia <therealgraysky@proton.me>
This commit is contained in:
		 John Audia
					John Audia
				
			
				
					committed by
					
						 Christian Marangi
						Christian Marangi
					
				
			
			
				
	
			
			
			 Christian Marangi
						Christian Marangi
					
				
			
						parent
						
							79af0593a3
						
					
				
				
					commit
					d0d6b8e183
				
			| @@ -0,0 +1,25 @@ | ||||
| --- a/arch/arm64/boot/dts/mediatek/mt7622.dtsi | ||||
| +++ b/arch/arm64/boot/dts/mediatek/mt7622.dtsi | ||||
| @@ -23,11 +23,17 @@ | ||||
|  	cpu_opp_table: opp-table { | ||||
|  		compatible = "operating-points-v2"; | ||||
|  		opp-shared; | ||||
| -		opp-300000000 { | ||||
| -			opp-hz = /bits/ 64 <300000000>; | ||||
| -			opp-microvolt = <950000>; | ||||
| -		}; | ||||
| - | ||||
| +		/* Due to the bug described at the link below, remove the 300 MHz clock to avoid a low | ||||
| +		 * voltage condition that can cause a hang when rebooting the RT3200/E8450. | ||||
| +		 * | ||||
| +		 * https://forum.openwrt.org/t/belkin-rt3200-linksys-e8450-wifi-ax-discussion/94302/1490 | ||||
| +		 * | ||||
| +		 * opp-300000000 { | ||||
| +		 *	opp-hz = /bits/ 64 <300000000>; | ||||
| +		 *	opp-microvolt = <950000>; | ||||
| +		 * }; | ||||
| +		 * | ||||
| +		 */ | ||||
|  		opp-437500000 { | ||||
|  			opp-hz = /bits/ 64 <437500000>; | ||||
|  			opp-microvolt = <1000000>; | ||||
		Reference in New Issue
	