All patches automatically rebased.
Acknowledgment to @john-tho for the changes to fs.mk to accommodate new paths
introduced in 29429a1f58
Build system: x86_64
Build-tested: bcm2711/RPi4B
Run-tested: bcm2711/RPi4B
Signed-off-by: John Audia <therealgraysky@proton.me>
		
	
		
			
				
	
	
		
			29 lines
		
	
	
		
			932 B
		
	
	
	
		
			Diff
		
	
	
	
	
	
			
		
		
	
	
			29 lines
		
	
	
		
			932 B
		
	
	
	
		
			Diff
		
	
	
	
	
	
From 3fb8841513c4ec3a2e5d366df86230c45f239a57 Mon Sep 17 00:00:00 2001
 | 
						|
From: Alexander Couzens <lynxis@fe80.eu>
 | 
						|
Date: Sat, 13 Aug 2022 13:08:22 +0200
 | 
						|
Subject: [PATCH 03/10] net: mt7531: ensure all MACs are powered down before
 | 
						|
 reset
 | 
						|
 | 
						|
The datasheet [1] explicit describes it as requirement for a reset.
 | 
						|
 | 
						|
[1] MT7531 Reference Manual for Development Board rev 1.0, page 735
 | 
						|
 | 
						|
Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
 | 
						|
---
 | 
						|
 drivers/net/dsa/mt7530.c | 4 ++++
 | 
						|
 1 file changed, 4 insertions(+)
 | 
						|
 | 
						|
--- a/drivers/net/dsa/mt7530.c
 | 
						|
+++ b/drivers/net/dsa/mt7530.c
 | 
						|
@@ -2248,6 +2248,10 @@ mt7530_setup(struct dsa_switch *ds)
 | 
						|
 		return -ENODEV;
 | 
						|
 	}
 | 
						|
 
 | 
						|
+	/* all MACs must be forced link-down before sw reset */
 | 
						|
+	for (i = 0; i < MT7530_NUM_PORTS; i++)
 | 
						|
+		mt7530_write(priv, MT7530_PMCR_P(i), MT7531_FORCE_LNK);
 | 
						|
+
 | 
						|
 	/* Reset the switch through internal reset */
 | 
						|
 	mt7530_write(priv, MT7530_SYS_CTRL,
 | 
						|
 		     SYS_CTRL_PHY_RST | SYS_CTRL_SW_RST |
 |