 706a4ec40c
			
		
	
	706a4ec40c
	
	
	
		
			
			Manually rebased:
    oxnas/patches-5.10/100-oxnas-clk-plla-pllb.patch
All other patches automatically rebased.
Build system: x86_64
Build-tested: ipq806x/R7800
Signed-off-by: John Audia <therealgraysky@proton.me>
		
	
		
			
				
	
	
		
			18 lines
		
	
	
		
			565 B
		
	
	
	
		
			Diff
		
	
	
	
	
	
			
		
		
	
	
			18 lines
		
	
	
		
			565 B
		
	
	
	
		
			Diff
		
	
	
	
	
	
| From: George Kashperko <george@znau.edu.ua>
 | |
| Subject: Issue map read after Write Buffer Load command to ensure chip is ready to receive data.
 | |
| 
 | |
| Signed-off-by: George Kashperko <george@znau.edu.ua>
 | |
| ---
 | |
|  drivers/mtd/chips/cfi_cmdset_0002.c |    1 +
 | |
|  1 file changed, 1 insertion(+)
 | |
| --- a/drivers/mtd/chips/cfi_cmdset_0002.c
 | |
| +++ b/drivers/mtd/chips/cfi_cmdset_0002.c
 | |
| @@ -2050,6 +2050,7 @@ static int __xipram do_write_buffer(stru
 | |
|  
 | |
|  	/* Write Buffer Load */
 | |
|  	map_write(map, CMD(0x25), cmd_adr);
 | |
| +	(void) map_read(map, cmd_adr);
 | |
|  
 | |
|  	chip->state = FL_WRITING_TO_BUFFER;
 | |
|  
 |